2114 – OWS oil moisture interface monitoring instrument Inferior victory ARJAY

Feb 25th, 2012

Brand: Other

Name: 2114 – OWS oil moisture interface monitoring instrument Inferior victory ARJAY

Type: 2114-OWS

About products:

2114- OWS oil moisture interface monitoring instrument – can monitor the thickness of oil reservoir the static water oil boundary continuously, and control it and the ultra limit calls the police

The products are detailed:

2114-OWS
Oil moisture interface monitoring instrument
— Can monitor the thickness of oil reservoir the static water oil boundary continuously, and control it and ultra limit calls the police
Performance and characteristic
There is no movable part
The standard paired line is connected
A controller can connect 2 detectors
Have safeguard procedures inside ones that can work in the hazardous area
Resist connecting the part of the liquid of corrosivity Tef lon, stainless steel material high
The technology of electric capacity that uses can be used in any type oils
The technology of high-frequency electric capacity does not need to be daily clean
Standard, the method to set up is succinct
Technical indicator
Control unit
Working temperature: 0 ℃- 60 ℃
Power: 24VDC or 110VAC, 220VAC
Simulation is exported: 4-20mA is proportional to thickness of oil reservoir
Interface: RS-485 Modbus
Reveal: Taking the liquid crystal in a poor light reveals the thickness of oil reservoir
Relay: 410mA, SPDT
Authorize: UL CSA CE
Outer cover: Type 4X, IP65 gathers carbonic acid ester
Measure the unit
Ambient temperature: 0 ℃- 60 ℃
Working temperature: -60 ℃- 55 ℃
Authorize: SA Class 1, Zone 1 and 2, Div 1 and 2, Groups A,B,C,D
ABSA-CRN #OF07450.2