SUNFAR square frequency converter M320-4T0075

Dec 20th, 2011

Brand: Sunfast is – all sides

Name: SUNFAR square frequency converter M320-4T0075

Type: M320-4T0075

About products:

The mechanical frequency converter of M320 series plastics is Shenzhen’s electric technological Co., Ltd. designs a specialized frequency converter developed for mechanical trade of plastics all sides, it is good to adjust the speed smoothly, the torque of low frequency is great, stability is high; Adjust the range 0- 200Hz of the speed, easy

The products are detailed:

Control panel of the frequency converter remote that SUNFAR is all sides

The mechanical frequency converter of M320 series plastics is Shenzhen’s electric technological Co., Ltd. designs a specialized frequency converter developed for mechanical trade of plastics all sides, it is good to adjust the speed smoothly, the torque of low frequency is great, stability is high; Adjust speed range 0& mdash; 200Hz is easy realize the course is automized; Start the low electric current, assault to system and electric wire netting small; The frequency converter is small, debug, maintenance easy to install; Having strengthened the stability of running of the electrical machinery, the apparatus service life of effective extension, reduce the maintenance cost.

About function:

1.Output power: 1.5~90KW.

2.To the mechanical trade of plastics is professional are designed.

3.Heat-dissipating tunnel and airtight design of way of mainly going back independently optimized, performance is more steady.

4.One pair of LED panels reveals, it is convenient for customer to control and debug at the same time; Copy the function, help customers carry on many frequency converter procedures and duplicate the work in keyboard parameter.

5.Output the automatic steady voltage function, the pulse width of the automatic output, dispel the impact on load of fluctuating of the electric wire netting.

6.Unique adaptive control technology, the automatic limit flows and presses and owes with the limit in running and inhibits and makes protection.

7.Multiple hardware and software protect the function, the interference-free technology of hardware that and optimizes.

8.Reach the association of the input channel of 29 kinds of frequency, set for, multi-functional and programmable to import ports.

9. V/F curve is abducted more and designed, it is flexible to dispose.

10.The intersection of communication and interface, RS485 of standard configuration, available the intersection of MODBUS and agreement, self-defining agreement all sides; Possess and link and control the function synchronously, realize easily other workers such as frequency converter, PLC, worker’s accusing of machine accuse of the interconnection of the apparatus.

Application:

Trades such as plastic machinery, rubber,etc..

Fail
Enter

Specified voltage, frequency

Three phases ( 4T) 380V; 50/60Hz

Three phases ( 2T) 220V; 50/60Hz

The voltage allows change range

Three phases ( 4T) 300V ~ 460V

Three phases ( 2T) 170V- 270V

Fail
Appear

Voltage

Three phases ( 4T) 0 ~ 380V

Three phases ( 2T ) 0- 220 V

Frequency

0- 200 Hz

Overload capacity

Long-term 110%; 150% 1 minutes; 180% 2 seconds

Control method

VVVF space voltage vector

Control the characteristic

Frequency

Settlement

Resolution ratio

Imitate the end to input

The largest output frequency 0.1%

The figure is presumed

0.01Hz

External pulse

The largest frequency 0.1%

Frequency

Precision

Simulation is input

Less than 0.2% of the largest output frequency

The figure is input

Presume less than 0.01% of the output frequency

External pulse

The largest output frequency Less than 0.1%

V/F curve
(the frequency characteristic of voltage)

The basis frequency presumes in 5- 200Hz arbitrarily, many node V/F curves are presumed arbitrarily

The torque is promoted

Presume manually: 0.0- 20.0% that amount exports

The automatic limit flows and presses with the limit

No matter in accelerating, moderating or course of running of steady state, all detect and examine electrical machinery stator electric current and voltage automatically, inhibit it in the range of allowing according to the unique algorithm

It is depressing to owe and make while running

Especially to the voltage of the low electric wire netting and user whose voltage frequently fluctuated of electric wire netting, even within the range of below voltage allowed, system can according to unique algorithm and can assign tactics while being incomplete also, maintain the longest possible running time

Typical function

The frequency is presumed

Simulation is input

At direct current pigeonholes 0-5V, 0-10V, direct electric current 0- 20mA ‘ and lower limit is available)

The pulse is input

Amplitude 5- 30V, frequency pulse signal within 50.0KHz

The figure is input

Operate the panel to presume, RS485 interface presumes, UP/DW end son controls, can also input and presume many kinds of associations with simulation

Output the letter Number

OC end son

Output

OC of No. two exports and exports (TA, TB, TC) with a route of troubles relay ,Reaches 16 kinds of meanings to choose

Simulation is exported

Two No. 0- 10V voltage signal or 0- 20mA electric current signal, upper and lower limits can be presumed respectively

Automatic steady voltage runs

Can choose dynamic steady voltage, static steady voltage, the intersection of steady voltage and 3 way according to need, in order to obtain steady operation result the most

Add, the time of moderating presumes

0.1S- 6000min can be presumed continuously, S-shaped, the mode is available sharply type

Operation function

The upper, lower frequency presumes, the frequency jumps and runs, transship the conduct to limit instead, automatic steady voltage runs, RS485 communication, the frequency is increased progressively, decreased progressively and controlled etc.

Apparent

Show

Operate the panel to reveal

State of running

Output frequency, export the electric current, output voltage, the electrical machinery rotational speed, presume the frequency, module temperature, feedbacking amount, simulation is input and exported etc.

Warning content

Failure logging six times recently, parameter records of 6 operation such as the output frequency, presuming the frequency, outputting electric current, output voltage, pressing, module temperature of direct current when the last trouble trips,etc.

Protection / warning function

Cross electric current, overvoltage, owe, press, the intersection of electron and hot relay, overheated, short out, internal the intersection of memory and trouble,etc.

Ring

Border

Environment temperature

-From 10oC to +50oC (not freeze)

Humidity around

90% are following ‘ Do not form the frost)

Surrounding environment

In the room (there is no sunshine to shine, not have corroding, flammable gas directly, oil-free fog, dust,etc.)

Above sea level

Lower than 1000m

Knot

Construct

Protect the grade

IP20

Cooling way

It is air-cooled to force

Install the way

Wall type

Parameter
Type

Function
Code

Name

Presume range and explanation

Minimum

Unit

Dispatched from the factory

Settlement

Change

Limit

Basically run in the parameter group

F0. 0

Operational mode

Keep

F0. 1

The frequency input channel / way is chosen

0: The frequency figure is presumed

1: UP/DW end son increases progressively, decreases progressively and controls

2: RS485 interface

3: Potentiometer of the panel

4: External a voltage signal VC1 ‘ 0~5V)

5: External a voltage signal VC2 ‘ 0~10V)

6: External a electric current signal CC ‘ 0~20 mA)

7: External a pulse signal ‘ 0.0~50.0 kHz)

8: Make up presuming

9: Carry the son to choose on the outside

1

0

F0. 2

The frequency figure is presumed

0.00 ~Frequency of upper limit

0.01

0

F0. 3

The frequency figure presumes that assists controlling

LED the unit:

0: Presume the frequency loses the electricity to store

1: Presume the frequency loses the electricity and does not store

LED ten:

0: Presume the frequency keeps while shutting down

1: Presume the frequency is returned to [F0.2 ] while shutting down

2: Presume the zero clearing of the frequency while shutting down

LED one hundred: Keep

LED kilobit: Keep

1

0000

F0. 4

Run and order the passway to choose

LED the unit:

0: The keyboard is controlled 1: External end son

2: Serial communication port

LED ten: STOP key function

0: Only the board control method opposite is effective

1: All control methods are effective

LED one hundred: Keep

LED kilobit: Keep

1

0000

F0.5

Operate the order and carry the sub mode of combination

0: Mode 1 of Line two 1: Line two mode 2

2: Mode of the strategic hinterland of China

1

0

F0.6

Change direction and control

LED the unit:

0: With presuming the direction is identical

1: With presuming the direction is opposite

LED ten:

0: Overturning prevents invalid 1: Overturning prevents effectively

LED one hundred: The outside runs the passway assists the function

0: Have electric self-starting to forbid

1: It allows to have electric self-starting

LED kilobit: : Keep

1

0100

F0.7

Lower frequency

0.0 Hz~ [F0.8]

0.01

0.0

F0.8

Frequency of upper limit

[F0.7] ~ 200.00Hz

0.01

50.00

F0. 9

Accelerate 1 of time

0.1 ~6000 seconds

0.1

F0. 10

1 of time of moderating

0.1 ~6000 seconds

0.1

F0. 11

Add, moderate the characteristic parameter

LED the unit:

0: The straight line is added and moderated; 1: S curve added and moderated

Ten location of LED- Kilobit: Keep

1

0000

F0. 12

S adds and moderates initial section

10 .0~ 50.0 ( %)

0.1

20.0

F0. 13

S adds and moderates to rise / drop section

10.0 ~80.0 ( %)

0.01

60.0

F0. 14

Frequency of the signal carrier

1.5~ 10.0 KHz

0.1

F0. 15

Carry Potter

LED the unit: Keep

LED ten:

0: Support the related signal carrier to adjust and close

1: Support the related signal carrier and adjust movements

LED one hundred:

0: The hot related signal carrier is adjusted and closed

1: The hot related signal carrier adjusts movements

LED kilobit:

0: The frequency signal carrier is adjusted and closed

1: The related signal carrier of frequency adjusts movements

1

1110

F0. 16

The parameter is written into and protects

1: Only permit to revise F0.2 and a parameter

2: Only permit to revise a parameter

Other number values: Allow to revise all parameters

1

0

Elementary application parameter group

F1. 0

V/F curve type chosen

0: Permanent torque contours

1: Self-defining V/F contours (parameter F1.1- F1.9)

1

0

F1. 1

The torque is promoted

0.0~20.0( % )

0.1

6.0

F1. 2

Basically operation frequency

5.00- Frequency of upper limit

0.01

50.00

F1. 3

The largest output voltage

60- 500V

30- 250V

1

380

220

F1. 4

V/F frequency 3

[F1.6] ~ [F1.2]

0.01

0.0

F1. 5

V/F voltage 3

[F1.7] ~ 100.0(%)

0.1

0.0

F1. 6

V/F frequency 2

[F1.8] ~ [F1.4]

0.01

0.0

F1. 7

V/F voltage 2

[F1.9] ~ [F1.5]

0.1

0.0

F1. 8

V/F frequency 1

0.0 ~[F1.6]

0.01

0.0

F1. 9

V/F voltage 1

[F1.1] ~ [F1.7]

0.1

0.0

F1. 10

The direct current while starting applies the brake in the electric current

0.0 -100.0( % )

0.1

50.0

F1. 11

Time of applying the brake of direct current while starting

0.0 -20.0 seconds

0.1

0

F1.12

Keep

Simulation inputs and outputs the parameter group

F2.0

VC1 inputs the lower voltage

0.0 V~ [F2.1]

0.1

0.0

F2.1

VC1 inputs the voltage of upper limit

[F2.0] ~ 5.0V

0.1

5.0 V

F2.2

VC2 inputs the lower voltage

0.0 V~ [F2.3]

0.1

0.0

F2.3

VC2 inputs the voltage of upper limit

[F2.2] ~ 10.0V

0.1

10.0V

F2.4

CC inputs the lower electric current

0.0 mA~ [F2.5]

0.1

4.0

F2.5

CC inputs the electric current of upper limit

[F2.4] ~20.0 mA

0.1

20.0

F2.6

The minimum pulse is input

0.0 KHz ~ [F2.7]

0.01

0.0

F2.7

The greatest pulse is input

[F2.6] ~50.00 KHz

0.01

10.0

F2.8

Minimum to presume the frequency

0.0~[F2.9]

0.01

0.00

F2.9

Presume the frequency the most largely

[F2.8]~ 200.0 Hz

0.01

50.00

F2.10

The input channel characteristic is chosen

LED the unit: (VC1 passway)

0: Straight characteristic 1: Go against the characteristic

LED ten: (VC2 passway)

0: Straight characteristic 1: Go against the characteristic

LED one hundred: (CC passway)

0: Straight characteristic 1: Go against the characteristic

LED kilobit: (pulse passway)

0: Straight characteristic 1: Go against the characteristic

1

0000

F2.11

The external frequency presumes that strains the wave

Time constant

0.01- 1.00 Sec

0.01

0.10

F2.12

Input channel association of the frequency

See, make up, prove ‘ 0- 29)

1

0

F2.13

Simulation is exported and chosen

(AO1, AO2)

LED the unit: AO1 exports and chooses

0: Output frequency 1: Export the electric current

2: Output voltage 3: The electrical machinery rotational speed

LED ten: AO2 exports and chooses

0: Output frequency 1: Export the electric current

2: Output voltage 3: The electrical machinery rotational speed

LED one hundred: Keep

LED kilobit: Keep

1

0010

F2.14

Simulation outputs AO1 lower limit

0.0- [F2.15]

0.1

0.0 V

F2.15

Simulation outputs AO1 upper limit

[F2.14]- 12.0

0.1

10.0V

F2.16

Simulation outputs AO2 lower limit

0.0- [F2.17]

0.1

2.0 V

F2.17

Simulation outputs AO2 upper limit

[F2.16]- 12.0

0.1

12.0

F2.18

Keep

The figure inputs and outputs the parameter group

F3.0

A function of input terminus son is controlled (0~19)

0 ~5: The control end is left unused;

6: Rotate clockwise and click moving to control;

7: Overturn and click moving to control;

8: Add the time of moderating to choose;

9: Keep

10: The frequency presumes the passway chooses 1;

11: The frequency presumes the passway chooses 2;

12: The frequency presumes the passway chooses 3;

13: The frequency is increased progressively and controlled (UP) ;

14: The frequency decreases progressively and controls (DW) ;

15: Zero clearing of UP-DW frequency;

16: Shut down and control freely;

17: External equipment fault;

18: The the strategic hinterland of China type operates and controls;

19: Direct current applies the brake to control;

1

1

F3.1

2 functions of input terminus son are controlled (0~19)

1

2

F3.2

3 functions of input terminus son are controlled (0~19)

1

3

F3.3

4 functions of input terminus son are controlled (0~19)

1

6

F3.4

5 functions of input terminus son are controlled (0~19)

1

13

F3.5

6 functions of input terminus son are controlled (0~19)

1

14

F3. 6

Export the port 1 to choose
( OC1)

0: In the frequency converter runs 1: The frequency arrives

2: Horizontal testing signal of the frequency 3: The overload calls the police

4: The external trouble shuts down

5: The frequency reaches upper limit 6: The frequency reaches lower limit

7: A 8 while operating rapidly: Owe and press and shut down

9~15: Keep 16: Trouble of the frequency converter

17: The power level is measured 18: Keep

1

0

F3. 7

Export the port 2 to choose
( OC2)

1

1

F3. 8

The relay is exported and chosen

(TA, TB, TC)

1

16

F3. 9

The frequency reaches the detection range

0.0- 20.00 Hz

0. 01

5.00

F3. 10

FDT (frequency level) Settlement

0.0- Frequency of upper limit

0.01

10.00

F3. 11

FDT exports the time of delay

0.0- 200.0 Sec

0.1

2.0

F3.12

Warning level of the overload

50- 200( % )

1

110

F3.13

Warning time delay time of overload

0.0- 20.0 Sec

0.1

2.0

F3.14

The power measures competence to presume

0- 200( % )

1

100

F3.15

The power measures the time of delay

0.0- 200.0 Sec

0.1

2.0

F3.16

Keep

Run in the parameter group auxiliarily

F4.0

Start the frequency

0.0- 10.00Hz

0.01

1.00

F4.1

Start the duration of frequency

0.0- 20.0 seconds

0.1

0.5

F4.2

Way of shutting down

0: Reduce the speed 1: Shut down freely

1

0

F4.3

Initial frequency that direct current applies the brake while shutting down

0.0- 50.00 Hz

0.01

3.00

F4.4

Direct current applies the brake for time of movement while shutting down

0.0- 20.0 seconds

0.1

0

F4.5

Direct current applies the brake in the electric current while shutting down

0.0- 100( % )

0.1

50.0

F4.6

A threshold of running frequently

0.0- 100.0 Hz

0.01

0.0

F4.7

A difference of going back frequently

0.0- 50.00 Hz

0.01

1.00

F4.8

Some moves frequency

0.0- Frequency of upper limit

0.01

10.00

F4.9

Accelerate the moment level

110- 200( % )

1

150

F4.10

Electrical machinery overload protection coefficient

50- 110( % )

1

110

F4.11

Automatic steady voltage (AVR)

0: Invalid; 1: The trends are effective;

2: The static behavior is effective; 3: It is invalid to moderate

1

0

F4.12

It is transferred to very much district time that positive and negative

0.0- 5.0 seconds

0.1

0.0

F4.13

Accelerate 2 of time / click and move and accelerate time

0.1- 6000 seconds

0.1

F4.14

Moderate 2 time / order and move the time of moderating

0.1- 6000 seconds

0.1

F4.15

UP/DW end son revises the speed

0.01- 100.0 Hz/Sec

0.01

10.00

F4.16

The frequency 1 jumps

0.0- Frequency of upper limit

0.01

0

F4.17

A range of frequency jumps

0.0- 5.00 Hz

0.01

0

F4.18

The frequency 2 jumps

0.0- Frequency of upper limit

0.01

0

F4.19

2 range of frequency jumps

0.0- 5.00 Hz

0.01

0

F4.20

The linear velocity coefficient is presumed

0.01- 100.0

0.01

1.00

F4.21

Control the parameter 1 to choose

0- 25

1

0

F4.22

Control the parameter 2 to choose

0- 25

1

1

F4.23

Inquire, revise the authority in parameter

0- 9999

1

1700

F4.24

Initialisation of parameter

0: Do not act 1: Standard initialisation

2: Remove the failure logging 3: Complete initialisation

1

0

F4.25

Copy the function in parameter

0: Copy and forbid 1: It allows to copy

1

1

F4.26

Producer’s password

0- 9999

1

1500

F4.27

Authority password

0- 9999

1

0

F4.28

Consult the password

0- 9999

1

Function parameter group of the communication

F5.0

Communication is set up

LED the unit: The Potter rate is chosen

0: Keep 1: 1200bps

2: 2400bps 3: 4800bps

4: 9600bps 5: 19200bps

LED ten: Data form chosen

0: There is no check-up 1: Even check-up 2: Strange check-up

LED one hundred: Keep

LED kilobit: Keep

1

0014

F5.1

This machine address

0- 30

1

0

F5.2

This machine replies the time of prolonging

0- 1000ms

1

5ms

F5.3

Communication assists the function to dispose

LED the unit: Principal and subordinate is set up

0: Originally change device frequently into it from the station;

1: Originally change device frequently into the main website

LED ten: Movement choice after communication fails

0: Shutting down; 1: Attitude of maintaining the statusquo

LED one hundred: Keep

LED kilobit: Link and control the synchronous frequency source

0: Presume the frequency

1: Output frequency

1

0010

F5.4

Communication overtime

0.0- 100.0s

0.1

10.0

F5.5

Link and presume the proportion

0.01- 10.00

0.01

1.00

F5.6

Link the proportion and correct the passway

0: Have not corrected 1: Potentiometer of the panel

2: External a voltage signal VC1 ‘ 0 ~ 5V)

3: External a voltage signal VC2 ‘ 0 ~ 10V)

4: External electric current signal CC (CC)

1

0

F5.7

Assist the frequency to presume the passway from the machine

0: There is no auxiliary frequency 1: Potentiometer of the panel

2: External voltage signal VC1 (0- 5V)

3: External voltage signal VC2 (0- 10V)

4: External electric current signal (CC)

1

0

F5.8

Auxiliary frequency range

0.0- 25.00 Hz

0.01

5.00

The special function disposes the parameter group

FC.0

Owe and press and protect competence

360- 460V

1

380

FC.1

Excessive pressure limits the movement level

660- 760V

1

720

FC.2

Electric current amplitude limiting level

150- 200( % )

1

180

FC.3

Keep

FC.4

Keep

FC.5

Function movements are chosen

LED the unit: Cool the fan to control

0: Cool the fan and operate after the frequency converter runs

1: Cool the electricity on the frequency converter of the fan, turn round immediately

LED ten: Keep

LED one hundred: The voltage passes and modulates

0: Close 1: Movements

LED kilobit: Keep

1

0000

FC.6

Keep

FC.7

Keep

FC.8

Keep

FC.9

Keep

FC.10

Keep

FC.11

Shake and inhibit the factor

0.10- 10.00

0.01

0.00

FC.12

Keep

FC.13

Procedure edition

5000- 5099

1

Recommend using the specification of the electric apparatus:

Basically mixing the line of frequency converter:

Installation size of the frequency converter

Applicable model: M320-4T0015~M320-4T0075 / M320– 2T0015~M320– 2T0037

Size Ⅱ of installation of the frequency converter

Applicable model: M320-4T0110- M320-4T0900/ M320-2T0055- M320-2T0550

Install the size:

Type of the frequency converter

(three-phase 380V)

Type of the frequency converter

(three-phase 220V)

W1

(mm)

W

(mm)

H1

(mm)

H

(mm)

D

(mm)

Screw
Specification

M320-4T0015

M320-2T0015

123

134

223

234

165

M4

M320-4T0022

M320-2T0022

M320-4T0037

M320-4T0055

M320-2T0037

157

169

282

294

178

M5

M320-4T0075

M320-4T0110

M320-2T0055

184

204

328

344

199

M6

M320-4T0150

M320-2T0075

M320-4T0185

M320-2T0110

200

230

400

420

211

M6

M320-4T0220

M320-2T0150

M320-4T0300

M320-2T0185

232

260

450

470

233

M8

M320-4T0370

M320-2T0220

M320-4T0450

M320-2T0300

271

300

545

567

250

M8

M320-4T0550

M320-2T0370

M320-4T0750

M320-2T0450

344

381

588

614

298

M8

M320-4T0900

M320-2T0550

No comments yet.